DSC control description

POSITION AUTO ACK

TEST

1 2 3 CANCEL

PRINT CONTRAST VOLUME

4 5 6

FILE RCVD XMTD

Figure 2-2 DSC keyboard

7

8

9

SELECT

 

0

 

ENT

Key

 

 

Function/Purpose

0

9

Enter numeric data.

 

 

CANCEL

Cancels wrong data and restores previous menu.

 

 

 

 

 

Adjusts illumination of LED and keys in four levels.

 

 

 

SELECT

1.

Displays Set up menu (Main menu).

 

 

2.

Changes settings of items appearing with blinking question mark.

 

 

 

ENT

 

Registers key input. (Blinking item is registered when key is pressed.)

 

 

 

 

 

 

1.

Shifts the cursor leftward.

 

 

2.

Restores previous display when pressed at displays with a blinking

 

 

 

question mark.

 

 

 

 

Shifts the cursor rightward.

POSITION

1Position and time are shown while pressed and held down.

AUTO ACK

Turns automatic transmission of acknowledge call (AUTO ACK) on/off. (Refer

2to page 2-8.) Note that distress alert cannot be automatically acknowledged by "auto acknowledge."

TEST

3Conducts self-tests.

PRINT

4

Printing. (Also sets up automatic printing.)

CONTRAST

5Adjusts contrast of LCD in eight levels.

FILE

7Opens files.

RCVD

Displays contents of received messages. (Storage capacity: 100 files, 50

 

8each of distress and other.) (Refer to page 4-20.)

XMTD

Displays contents of transmitted messages. (Storage capacity: 50 files.)

 

9(Refer to page 4-20.)

VOLUME

Not used.

6

2-3