3.WIRING OF OPTIONAL EQUIPMENT

3.1NBDP Terminal DP-6

The NBDP Terminal connects to the REMOTE connector on the FS-1503. It has a remote control function which automatically sets class of emission and frequency data at the FS-1503.

Remarks on connection

Connect the NBDP Terminal to the FS-1503 with a 13-pair twisted cable. For the cable with no connectors, attach connector types SRCN (at FS-1503) and D-sub (at DP-6). For cable with D- sub connector, connect the SRCN connector at the FS-1503 side.

Necessary parts, interconnection

Requires REMOTE-A Kit. Install the board following the illustration on page 3-3. Note that a narrow bandpass filter is also available. For connection, interconnection diagram on page S-1.

Contents of REMOTE-A Kit OP05-82 (Code no. 005-939-810)

Name

Type

Code No.

Qty

 

 

 

 

REMOTE PCB

05P0457

005-840-980

1

 

 

 

 

Connector Assy.

05S0928

000-130-440

1

(REMOTE connector)

 

 

 

 

 

 

 

3.2 DSC Terminal DSC-60

The DSC Terminal connects to the REMOTE connector on the FS-1503.

Remarks on connection

When both the NBDP Terminal and DSC Terminal are to be connected, connect them via the Distributor DB-500.

Necessary parts, interconnection

Requires REMOTE-A Kit. Install the board following the illustration on page 3-3. Note that a narrow bandpass filter is also available. See the interconnection diagram on page S-1.

3-1