Furuno GP-1850DF Attaching the transducer, Coating the transducer face with silicone sealant

Models: GP-1850DF

1 63
Download 63 pages 6.35 Kb
Page 11
Image 11

Attaching the transducer

1.Clean the transducer face to remove any foreign material. Lightly roughen the transducer face with #100 sandpaper. Also, roughen the inside of the hull where the transducer is to be mounted.

2.Warm the silicone sealant to 40°C before usage to soften it. Coat the trans- ducer face and mounting location with silicone sealant.

Transducer face

Silicone sealant

Figure 1-6 Coating the transducer face with silicone sealant

3.Press the transducer firmly down on the hull and gently twist it back and forth to remove any air which may be trapped in the silicone sealant.

Squeeze out air bubbles.

Hull

Silicone sealant

Figure 1-7 Attaching transducer to hull with silicone sealant