DLM 600W Series

Isolated Remote Analog Interface Operation

CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22 provides a 1mA current source which would be connected to Pin-10, CURRENT PROGRAMMING INPUT, with a 0-5kΩ external resistor connected between Pin-22 to Pin-12, to program the output current from

0-100% of full scale output. The INTFC SETUP switch Position-2, I, must be set to OFF (down) to select 0-5VDC input range. Circuit is SELV, and has electrical isolation from the output of the unit.

Auxiliary Sources

AUXILIARY 5VDC OUTPUT: Pin-15, 5VDC source output for use with logic and programming circuits. Source capability is adequate to provide for full scale programming of output voltage, current, or OVP when the user connects it to the appropriate programming input(s). Source is referenced to Pin-6. Maximum output current is 15mA. Circuit is SELV, and has electrical isolation from the output of the unit.

AUXILIARY 5VDC RETURN: Pin-6, return of 5VDC AUXILIARY source output. Circuit is SELV, and has electrical isolation from the output of the unit.

1.25VDC REFERENCE FOR 4-20mA VOLTAGE PROGRAMMING: Pin-20, provides a 1.25VDC reference utilized by internal circuits associated with 4-20mA programming of output voltage.

1.25VDC REFERENCE FOR 4-20mA CURRENT PROGRAMMING: Pin-11, provides a 1.25VDC reference utilized by internal circuits associated with 4-20mA programming of output current.

2.4Remote Programming Configuration

Table 2–3presents the options for remote control operation. Pin numbers refer to the ISOLATED ANALOG INTERFACE connector. Switch position numbers refer to the INTFC SETUP switch on the rear panel.

Mode ofANALOG-LCK-OUT, INTFCPower-UpLocal/Remote

CONTROL

Setup Switch

Operation

State

Toggling

Signal, Pin-1Position-7

 

 

 

Remote Only

High Level

ON (Up)

Remote

No

 

 

 

 

 

Local Only

Low or Open

Off (Down)

Local

No

 

 

 

 

 

Local/Remote

High Level

OFF (Down)

Remote

Yes

Table 2–3. Remote Programming Configuration Options

M51A Option