DLM 600W Series

Isolated Remote Analog Interface Operation

3.Connect a jumper from Pin-13 to Pin-12.

4.Connect a jumper from Pin-11 to Pin-23.

5.Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.

6.Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15.

2.5EXTERNAL-OFF Control

The EXTERNAL-OFF control input provides the same functionality as the OUTPUT switch on the front panel. When asserted, it will turn off the output converter, discharge the output capacitors with the downprogrammer, and reset the OVP and FAULT monitors. The signal could be configured to be either active-low or active-high with the INTFC SETUP switch on the rear panel.

Set Position-6, /EXT-OFF, to the OFF (down) position to select the active-high logic level for asserting EXTERNAL-OFF. Set Position-6, /EXT-OFF, to the ON (up) position to select the active-low logic level for asserting EXTERNAL-OFF. The logic-high level could be produced with a voltage source within the range of 3-30VDC, and would be connected to Pin14, positive, and Pin-2, return. The circuit is SELV, and has electrical isolation from the output of the unit.

2.6Remote Monitoring

Analog signals are available for monitoring the output voltage and current. These signals vary proportionally to the output parameters, and have user selectable ranges of 0-5VDC, 0-10VDC, or 4-20mA for an output change from zero to full scale. Refer to Table 2–4for information on configuring the monitors.

OutputISOLATED ANALOG

 

INTFC SETUP SwitchSignal

Monitor

INTERFACE Connections

 

 

 

 

Range

Signal

Signal

Return

 

Position

Setting

 

 

Voltage

Pin-19

Pin-2

 

4, VMON

OFF (down)

0-5VDC

Voltage

Pin-19

Pin-2

 

4, VMON

ON (up)

0-10VDC

 

 

 

 

 

 

 

Voltage

Pin-4

Pin-6

 

4, VMON

OFF (down)

4-20mA

 

 

 

 

 

 

 

Current

Pin-7

Pin-2

 

5, IMON

OFF (down)

0-5VDC

Current

Pin-7

Pin-2

 

5, IMON

ON (up)

0-10VDC

 

 

 

 

 

 

 

Current

Pin-24

Pin-6

 

5, IMON

OFF (down)

4-20mA

 

 

 

 

 

 

 

 

 

Table 2–4.Remote Monitoring

 

M51A Option