DLM 600W Series

Isolated Remote Analog Interface Operation

4.Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to Pin-12.

5.Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15.

2.4.4Resistance Programming of Output Voltage

Setting up for resistance programming of the output voltage is as follows:

1.Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range.

2.Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG INTERFACE connector, from Pin-21 to Pin-12.

3.Connect a jumper from Pin-21 to Pin-9.

4.Program the other parameters to the desired limit values: CURRENT PROGRAMMING INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12.

5.Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15.

2.4.5Resistance Programming of Output Current

Setting up for resistance programming of the output current is as follows:

1.Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range.

2.Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG INTERFACE connector, from Pin-22 to Pin-12.

3.Connect a jumper from Pin-22 to Pin-10.

4.Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12.

5.Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15.

M51A Option