Isolated Remote Analog Interface Operation

DLM 600W Series

2.4.1Voltage Source Programming of Output Voltage

Setting up for voltage source programming of the output voltage is as follows:

1.Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range.

2.Set Position-1, V, of the INTFC SETUP switch ON (up) for 0-10VDC programming range.

3.Connect the external programming voltage source to the ISOLATED ANALOG INTERFACE connector, with positive to Pin-9 and negative to Pin-12.

4.Program the other parameters to the desired limit values: CURRENT PROGRAMMING INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.

5.Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15.

2.4.2Voltage Source Programming of Output Current

Setting up for voltage source programming of the output current is as follows:

1.Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range.

2.Set Position-2, I, of the INTFC SETUP switch ON (up) for 0-10VDC programming range.

3.Connect the external programming voltage source to the ISOLATED ANALOG INTERFACE connector, with positive to Pin-10 and negative to Pin-12.

4.Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.

5.Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15.

2.4.3Voltage Source Programming of OVP

Setting up for voltage source programming of OVP is as follows:

1.Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range.

2.Set Position-3, OVP, of the INTFC SETUP switch ON (up) for 0-10VDC programming range.

3.Connect the external programming voltage source to the ISOLATED ANALOG INTERFACE connector, with positive to Pin-3 and negative to Pin-12.

2-8