Gardena C 1030 plus Art. 1862 The normal display appears on the screen again, The valve is closed

Models: C 1030 plus Art. 1862

1 15
Download 15 pages 9.92 Kb
Page 9
Image 9
1.

Exit soil moisture sensor- controlled watering again:

Read / modify watering programmes:

1.

Manual operation:

1.

2.

The watering duration is preset to 30 minutes at the factory.

Emergency programme: If no sensor is inserted in sensor-con- trolled watering mode or if the connection cable is faulty, watering will take place every 24 hours. The watering duration depends on the run time but is limited to a maximum of 30 minutes.

vHold the Menu button down for 5 seconds.

The normal display appears on the screen again.

If a value in the programme is to be changed, this can be changed without changing the other values in the programme.

1.Press the Menu key twice.

Start and the hours flash on the display.

2.Press the Menu button to jump to the next programme level

– or –

change the programme data with the rotary button and confirm by pressing the OK button.

When the watering duration is changed while a program is running, the current watering cycle is ended.

The valve can be opened or closed manually at any time. A program-controlled open valve can also be closed early without changing the program data (watering start time, watering duration and watering frequency).

The controller must be fitted.

1.Press Man.-key to open the valve manually (or to close an open valve).

Run Time and the watering time in minutes (set to 30 minutes in the works) flash for 10 seconds on the display.

2.Whilst the watering time in minutes is flashing, the watering

duration can be modified with the rotary button (between

0 : 00 and 0 : 59 ) (example: 1 0 minutes) and confirm with the OK-key.

3.Press Man.-key to close the valve early.

The valve is closed.

The amended manual opening period is stored, i.e. each time the valve is opened manually in future the modified opening period is preset. If the manual opening period is amended to 0 : 00, the valve is closed and also remains closed after the Man.-key is pressed (child lock).

If the valve has been opened manually and a programmed start of a watering period overlaps the manual opening period, the programmed starting time is suppressed.

Example:

The valve is opened at 9.00 a.m. manually, the opening period is 30 minutes. A program with a start time (START) between 9.00 and 9.30 a.m. will not be undertaken in this case.

GB

9

Page 9
Image 9