SERVICING continued
Gas Valve Regulator
The gas valve regulator (See fig 4) used on the griddle is AGA and CGA approved.. The direction of gas flow is at right angles, right and left viewing the inlet.. For setting the regulator:
•For natural gas, Part #240510 regulator, set at 3..5”W..C.. at 22 CFH air each side at 7”W..C.. inlet pressure.. Regulator adjustment range is 2..8” to 4..0”WC..
•From propane, part # 245101 regulator, set at 10..0”W..C..
Figure 4 – Gas Valve Regulator
Power Switches
Dust caps fitted on the main power switch and zone switches protect them from dust and the corrosive effect of cooking fumes.. If the dust caps are removed, or not replaced following servicing, the switches will deteriorate and have reduced life expectancy.. Replace the dust caps following servicing..
Control Circuit
Figure 4 shows the control schematic for the
Flow
Inlet
Flow
Pressure
setting screw
Turn
Turn clockwise to decrease the pressure