Garland CG-60, CG-24, CG-36, CG-48, CG-72 service manual Dimensions And Specifications

Models: CG-60 CG-72 CG-48 CG-36 CG-24

1 20
Download 20 pages 17.04 Kb
Page 4
Image 4
DIMENSIONS AND SPECIFICATIONS

DIMENSIONS AND SPECIFICATIONS

INSTALLATION NOTES

SPECIFY GAS TYPE

ELECTRICAL CHARACTERISTICS

 

 

 

 

 

Combustible Wall Clearances

Operating Pressure

Specifications

 

 

 

 

 

Sides:

Back:

Natural:

Propane:

120 V, Single Phase, 60Hz, 1 amp

6" (152mm)

6" (152mm)

7" W..C.. (17.4mbar)

11" W..C.. (24.4mbar)

6' (1829mm) power supply cord provided..

 

 

 

 

 

• IMPORTANT: Unit must be

• Gas Input Ratings shown are for

 

installations up to 2,000 feet (610mm)

• NOTE: No cord and plug on export units..

installed on legs for proper air

above sea level.. BTU input ratings must be

Direct connection on junction box..

circulation..

 

 

derated for high altitude installations..

 

 

 

 

 

 

 

ENTRY CLEARANCE

VENTILATION

EXPORT VOLTAGES

 

 

 

 

Crated

Uncrated

• Commercial cooking equipment requires

• NOTE: Export voltages are available on

 

 

an adequate ventilation system.. For

request..

40" (1016mm)

38" (965mm)

additional information, refer to the

 

 

 

220-240 volt, 50 Hz, 0.4 amps, single

• See illustration for further

National Fire Protection Association’s

phase..

specifications & size statistics

standard NFPA96..

 

 

 

 

 

 

 

 

 

 

 

 

Available in 24, 36, 48, 60 & 72 Widths

610, 914, 1219, 1524 & 1829

3" [76mm] Extended Bumper

Manual backgroundManual backgroundManual background to Prevent Flue Vent Blockage Manual backgroundManual background 2.5 84

3.25

83

 

 

 

Grease Trough

20

 

 

 

 

 

 

 

 

 

 

Gas Connection Centered

508

 

 

 

 

 

 

 

On Unit Width [Left to Right]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

38.75 610

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

984

 

 

 

 

Electric

 

 

 

 

 

 

 

 

5.5

 

 

 

 

 

 

 

 

 

 

Cord/Connection

 

 

140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

152

1.5

 

 

 

 

 

5

 

PLAN VIEW [Model CG-48R]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

 

 

 

 

 

 

Dimensions - All Models

 

 

 

 

 

127

 

 

Grease Drawer(s)

 

2' & 3' Units - One

 

4', 5' & 6' Units - Two

Finished Floor

Optional Stand

 

 

 

 

 

DIMENSIONS:

Inches

 

 

 

 

mm

5.75

 

0.625

 

 

 

 

 

 

16

 

 

 

 

 

146

 

 

 

Cooking Surface

 

 

 

 

Electric Cord/Connection

15.75

 

10

 

400

 

 

Gas Connection

Rear

 

254

 

 

 

 

 

 

 

 

Gas Inlet

 

 

 

 

 

 

 

 

4.75

 

 

 

 

6

35

121

 

 

 

 

 

Counter

 

Counter152

 

 

 

 

889

15

 

Removable

Leg

 

 

 

 

Optional

Grease

 

 

 

 

381

Stand

Drawer 27

 

 

 

 

 

 

686

 

 

 

Finished 10 Floor 254 Manual background

SIDE VIEW

INPUT CHART - Natural Or Propane Gas

Model

BTU/

 

Gas

Shipping

Kw

Weight

Number

HOUR

 

Inlet

 

 

Lbs../Kgs..

 

 

 

 

 

 

 

 

 

CG-24R

60,000

17..60

3/4"

335/152

 

 

 

 

 

CG-36R

90,000

26.40

3/4"

485/220

 

 

 

 

 

CG-48R

120,000

35..00

3/4"

625/284

 

 

 

 

 

CG-60R

150,000

44..00

3/4"

765/348

 

 

 

 

 

CG-72R

180,000

52..70

1"

995/411

 

 

 

 

 

FRONT VIEW [Model CG-48R]

Page 

Part #GCGTRAINING06 (03/03/08))

Page 4
Image 4
Garland CG-60, CG-24, CG-36, CG-48, CG-72 service manual Dimensions And Specifications