Garland EM-C180 Test Procedures And Troubleshooting, Primary, Windings, Secondary, Filament

Models: EM-C180

1 28
Download 28 pages 23.4 Kb
Page 6
Image 6
6. TEST PROCEDURES AND TROUBLESHOOTING

6. TEST PROCEDURES AND TROUBLESHOOTING

PRIMARY

 

 

 

CAUTION

WINDINGS

-DISCONNECT THE POWER SUPPLY CORD FROM THE WALL

Secondary

OUTLET WHENEVER REMOVING THE CABINET FROM THE UNIT.

Windings

PROCEED WITH TESTS ONLY AFTER DISCHARGING THE HIGH

 

VOLTAGE CAPACITORS AND REMOVING THE LEAD WIRES ON

 

THE PRIMARY WINDING OF THE HIGH VOLTAGE TRANSFORM-

 

ERS FOR LOWER AND UPPER MAGNETRONS.

Filament

(SEE FIGURE 3)

 

 

Windings

 

 

A. TEST PROCEDURES

Figure 3

 

 

COMPONENT

CHECKOUT PROCEDURE

RESULT

 

1) Check for resistance: Across the filament ter-

Normal reading:

MAGNETRON

minal of the magnetron with an ohm - meter

Less than 1 ohm.

on Rx1 scale.

 

 

 

Figure 4

 

2) Check for resistance: Between each filament

Normal reading:

terminal of the magnetron and the chassis

Infinite ohms.

ground with an ohm-meter on highest scale.

 

 

Figure 5

 

 

 

 

 

1) Measure the resistance:

Normal reading:

HIGH-VOLTAGE

With an ohm-meter on R x1 scale.

 

a. Primary winding;

Approximately 1.0 ohms

TRANSFORMER

b. Filament winding;

Less than 1 ohm.

 

 

c. Secondary winding;

Approximately 60 ohms

 

2) Measure the resistance:

Normal reading:

 

with an ohm-meter on highest scale.

 

 

a. Primary winding to ground;

Infinite ohms.

 

b. Filament winding to ground;

Infinite ohms.

Figure 6

Note: Remove varnish of measured point.

- 6 -