WARNING:
When removing the cabinet, you must disconnect the power supply cord from the wall oulet for your safety. Only the checkout procedure below needs the power supply on. TAKE GREAT CARE to avoid possible electrical shock.
For your safety, proceed with the test only after removing the wire leads from the pri- mary winding of the high voltage transformer
Primary
Winding
Lower
Primary
Winding
Upper
COMPONENT | CHECKOUT PROCEDURE | RESULT |
| |
| Check voltage at S104 and S105 after remov- | Normal reading: | ||
POWER | ing each connector (female) from power circuit | Connection |
| |
board. |
| |||
P.C.B |
| |||
Pin No.3 (Ground) and 4,5, 1,2 at S105. | Pin No., | Voltage(V) | ||
| ||||
| Pin No.1 and 2 at S104. | S105 |
| |
|
| #3 to #4 | DC 12 | |
| CAUTION: | #3 to #5 | DC 16 | |
| For your safety, proceed with the test only | #3 to #1 | DC 30 | |
| after removing the wire leads from the pri- | #3 to #2 | DC 35 | |
| mary winding of high voltage transformer. | S104 |
| |
| Test procedures: |
| ||
| a) Make sure that the power supply cord is not | #1 to #2 | AC 2.4 | |
| plugged in. |
|
| |
| b) Remove the connector S104 and S105 from |
|
| |
| the power circuit board. |
|
| |
| c) Plug the power supply cord : back in. |
|
| |
| d) And then, measure each voltage. |
|
| |
|
|
|
| |
| Measure the voltage: Between test points |
|
| |
CONTROL | Test point |
| ||
23) |
| |||
P.C.B | TP, | Voltage(V) | ||
| ||||
| Note | DC - 5 | ||
| - Proceed with the check of the control P.C.B to | |||
| DC - 12 | |||
| see if any one of the measured values is differ- | |||
| DC - 16 | |||
| ent from the specified values. | |||
| DC - 35 | |||
|
| |||
|
|
|
|
- 9 -