Part # 1382677 (08/06) Page 9
INSTALLATION Continued
E. e manifold of this unit or the mani fold of which
is a part of must be equipped with a certified
pressure regulator suitable for batter y application
and adjustable for an outlet pressure at the manifold
as specified on the rating place
Assembly Instructions M-Series Low Profile Backguard
1. Remove flue cap #6 by removing six (6) [#10] sheet
metal screws.
2. Remove front panel #5 by lifting upward.
3. With back panel #4 still att ached to the left #2 and
right #3 uprights, drop uprights into the rectangular
cutouts at the rear of the range #1.
4. Fasten uprights #2 and #3 to the range #1 with four
(4) 5/16” -18 bolts and flat washers #7 and #8.
5. If unit is in a batter y lineup, fasten adjacent units
together at hole marked “X” with ¼” -20 bolts,
nuts, and washers.
6. Insta ll front panel #5 previously remove
7. Insta ll flue cap #6 previously removed
~
~
1
"X"
"X"
2
5
8
7
3
6
9
4
Assembly Instructions M-Series Backguard
1. Remove front panel #5 by lifting upward.
2. With back panel #4 still att ached to the left #2 and
right #3 uprights, drop uprights into the rectangular
cutouts at the rear of the range.
3. Fasten uprights #2 and #3 to the range #1 with four
(4) 5/16” -18 bolts and flat washers #6 and #7.
4. If unit is in a batter y line up, fasten adjacent units
together at hole marked “X” with ¼” -20 bolts and
washers.
5. Insta ll front panel #5 previously removed. Attach
front panel #5 to range #1 with sheet metal screws.
1
"X"
"X"
25
8
4
3
6
7