OPERATING INSTRUCTIONS > THE ADJUSTMENT BAR

The Adjustment Bar

The Adjustment Bar allows quick access to the settings most commonly changed while using the unit. The Adjustment Bar settings are: Range, Gain, Scroll, Zoom, and View.

Press the MENU key to view the current Adjustment Bar settings. Press MENU again to hide the window. The current adjustment option always appears in the upper left of the display. Press left or right on the Arrow keys to scroll through the available options.

To immediately change the current adjustment option, press the up or down Arrow key. To review the available settings before making a change, press the ENTER key to activate the adjustment window.

To change a setting on the unit:

1.Press MENU, use the up or down Arrow key.

2.Move the selection arrow to the option you want, and press

ENTER.

3.Choose Setup for the main Setup Menu.

Range

Sets the display depth range. The unit can automatically track the bottom, or be set to a user-specified range. Available settings are: Auto (default) or 5-900 ft.

Gain

Controls the sensitivity of the unit’s sonar receiver. This provides some flexibility in what is seen on the display. To see more detail, increase the receiver sensitivity by selecting a higher gain (+). If there is too much detail or if the screen is cluttered, lowering the sensitivity (-)

may increase the clarity of the display. Available settings are: Auto (default) and 0-100%. The Auto setting level is controlled by the Auto Gain setting in the Setup menu.

Scroll

Adjusts the rate that the graph scrolls from right to left. If you are sitting still or the graph is moving too fast, slowing or pausing the graph can be beneficial.

14

Fishfinder 160C Owner’s Manual