Installation
used. Connect the other terminal of the switch to ground. The intercom function is enabled when the input is pulled low to ground.
SERIAL INTERFACE
The SL40 includes an RS232 serial port, which can be used for inputting frequency and function control commands and outputting transceiver status. This is an optional connection.
When making serial connections to the SL40, use a shielded three conductor cable. Make the RxD, TxD, and ground connections on the 15 pin connector. Connect the shield to the rear of the mounting frame on the connector plate.
The SL40 can be connected to the
Complete serial interface specifications are included in Appendix E.
ANTENNA INSTALLATION AND CONNECTIONSThe SL40 requires a standard 50: vertically polarized antenna. Follow the antenna manufacturer’s installation instructions for mounting the antenna.
The antenna should be mounted on a metal surface or a ground plane with a minimum area of 18 x 18 inches. The antenna should be mounted a minimum of 24 inches away from GPS antennas.
The comm antenna should also be mounted as far apart as practical from the ELT antenna, preferably one on top and the other on the bottom of the aircraft fuselage. Some ELTs have exhibited
The antenna coax cable should be made of
8 | Apollo SL40 Installation Manual |