CSG14 Series Gigabit Converter Switch

Installation and User Guide (05/08)

3.8.4Connecting Single-Mode Fiber Optic

When using single-mode fiber cable, be sure to use single-mode fiber port connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at longer distances, about 70km with the single-mode LC.

The same procedures as for single-mode fiber apply to multi-mode fiber connectors. Follow the steps listed in Section 3.8.3 above.

3.8.5Power Budget Calculations for CSG14 Series, Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:

OPB (Optical Power Budget) = PT(min) - PR(min)

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

www . GarrettCom . com

52

Page 60
Image 60