CSG14 Series Gigabit Converter Switch

Installation and User Guide (05/08)

The connection procedure is straightforward. Simply insert the DC leads to the CSG14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) optional; it connects to the CSG14H chassis. Ensure that each lead is securely tightened from the top, as shown here.

NOTE: Always use a voltmeter to measure the voltage of the incoming power supply and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post-labeled “+ve” and the rest to the “-ve”.

The GND can be hooked up at the last.

When power is applied, the green PWR LED will illuminate.

3.8 Connecting Ethernet Media

The Magnum CSG14 Series Converter Switch can be connected to two media types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be

www . GarrettCom . com