2.8 TERMINAL CONNECTION

2.8TERMINAL CONNECTION

2.8.1Requirements for Connecting Programming Terminal

The programming terminal must be connected with a serial cable with an RS-232C connector at the EIA port. This must be a null modem cable. This enables system administration (system setup, mailbox setup, and system diagnosis) to be performed.

Communication parameters of the VPS have been set to the following values at the factory:

Table 6

COMMUNICATION PARAMETERS

Baud Rate:

9600 bps

Word Bit Length:

8 Bits

Parity:

None

Stop Bit Length:

1 Bit

2.8.2Connecting the RS-232C Cable

STOP:

Before connecting the cable, make sure the power switches on both the data terminal and the VPS are OFF.

VOICE PROCESSING SYSTEM

POWER

Insert the RS-232C cable into the VPS with the connector indicating the same direction.

The cable must be shielded and no longer than 2m {6.5 feet}.

INSTALLATION

37