2.8 TERMINAL CONNECTION
INSTALLATION 37
2.8 TERMINAL CONNECTION

2.8.1 Requirements for Connecting Programming Terminal

The programming terminal must be connected with a serial cable with an RS-232C connector
at the EIA port. This must be a null modem cable. This enables system administratio n (system
setup, mailbox setup, and system diagnosis) to be performed.
Communication parameters of the VPS have been set to the following values at the factory:

2.8.2 Connecting the RS-232C Cable

STOP:

Before connecting the cable, make sure the power switches on both the data terminal and
the VPS are OFF.
Insert the RS-232C cable into the VPS with the connector indicating the same direction.
The cable must be shielded and no longer than 2m {6.5 feet}.
Tabl e 6
COMMUNICATION PARAMETERS
Baud Rate: 9600 bps
Word Bit Length: 8 Bits
Parity: None
Stop Bit Length: 1 Bit
POWER