5.4 AUTOMATED ATTENDANT PARAMETERS

To light Message Waiting Lamp at Operator 1's extension: Assign Mailbox 998 to Operator 1's extension. This will notify Operator 1 of messages left in the GDM.

Operators 2 and 3:

For KX-TD816 and KX-TD1232, Operators 2 and 3 can be assigned to a floating number that is assigned to a ring group.

Return to Program - Service Settings - Auto. Attn. Setting Menu:

Enter The Number : = 2

Program - Service Settings - Auto. Attn. Setting - Operator's Parameters Menu

1.Day Mode

2.Night Mode

SELECT ITEM AND PRESS KEY

1.Operator 1

2.Operator 2

3.Operator 3

SELECT ITEM AND PRESS KEY

Enter the data using the table below as a guide. The table below is for Operator 1 as example. Please refer to it for Operators 2 and 3.

 

 

 

Table 23

 

 

 

 

Description

 

Value Range

Description/Function

 

 

(Default)

 

 

 

 

 

Operator

1.

Disable

Enables or disables operator service.

Service

2.

Enable

 

 

 

(Enable)

 

 

 

 

 

Operator's

 

1-5 Digits

Specifies the operator's extension.

Extension

 

(0)

 

 

 

 

 

Operator's

 

2-5 Digits

Specifies Operator 1's mailbox number. Also

Mailbox No.

 

(998)

specifies General Delivery Mailbox.

 

 

 

 

Operator No

 

10-60 s

If a call transferred to Operator 1, 2, or 3 is not

Answer Time

 

answered within this period of time, the VPS uses

 

(30)

 

 

the No Answer Coverage Mode.*1

 

 

 

 

 

 

 

Busy

1.

Hold

Specifies the treatment of calls when Operator 1 is

Coverage

2.

No Answer Coverage

busy. If "Call Waiting" is chosen, Operator 1 is

Mode

3.

Call Waiting

signaled when another call is waiting using the Call

 

Waiting feature of the PBX.

 

4.

Disconnect Message

 

 

 

 

(Hold)

 

 

 

 

 

CUSTOMIZING THE SYSTEM

115

Page 115
Image 115