B7 SYSTEM ADMINISTRATION - HARDWARE SETTINGS
SYSTEM ADMINISTRATOR'S GUIDE 247
B7.2 Port Setting

Port Setting Menu

Note
The port assignment procedure for Port 2 is the same as Port 1.
To select Port Setting, follow the menu path as shown:
System Administration Top Menu - 1 - 6 - 2
To select the Port Setting Menu for Port 1, follow the menu path as shown:
System Administration Top Menu - 1 - 6 - 2 - 1
Tabl e 64
Parameter Value Range
(Default) Description/Function
Flash Time 1. 100 ms
2. 300 ms
3. 600 ms
4. 900 ms
(600)
Specifies the length of time the hook switch must be
pressed before the PBX will recognize it as a flash hook
signal. See the PBX manual to determine the correct
value.
CPC Signal 1. None
2. 6.5 ms
3. 150 ms
4. 300 ms
5. 450 ms
6. 600 ms
(None)
Specifies the minimum time necessary to detect an
interruption in the CPC (Calling Party Control) signal
received from the PBX. The VPS is able to determine
that the line has been disconnected when an
interruption of the CPC signal has been detected.
Disconnect
Time 1-8 s
(2) Specifies the length of time the line is temporarily
unavailable after a call has ended.
Dial Mode 1. DTMF
2. Pulse 10 pps
3. Pulse 20 pps
(DTMF)
Specifies the dial mode for DTMF or Pulse. If P ulse is
specified, pulse speed (10/20 pps) must be selected.
Note: This setting only affects outward dialing from the
VPS. The VPS can only receive DTMF signals.