CONNECTING PELCONET TO THE COM IN RS-232 PORT ON A GENEX MULTIPLEXER

Refer to Figure 42 and the instructions that follow.

PELCONET TRANSMITTER

POWER

ETHERNET 10/100 BASE-T

RS-232/422/485

OUTPUTS

INPUTS

AUDIO OUT

AUDIO IN

VIDEO 4

￿

TO NETWORK

￿

 

9600, 8, ODD, 1

DB9

 

4

5

 

TX+

3

6

 

 

 

 

TX-

2

7

 

 

1

8

 

RX+

 

 

 

RX-

 

 

 

 

 

STRAIGHT

￿

 

 

CABLE

￿

 

 

 

VIDEO 3

VIDEO 2 VIDEO 1

￿

PELCONET DB9

GENEX COM IN

 

ADAPTER

RJ-45 CONNECTOR

 

 

TX+

1

RX+

￿

 

TX-

2

RX-

 

 

RX+

8

TX+

 

 

RX-

7

TX-

 

GENEX COM

818 1

IN OUT

Figure 42. Connecting PelcoNet to Genex Using the COM IN RS-232 Port

￿Verify that the multiplexer has Version 4.1 firmware. (The version number flashes on the monitor when power is applied to the multiplexer.)

￿Set the NET104A data port to Transparent, 9600 baud, 8 data bits, none (for parity), 1 stop bit, RS-232,and half duplex mode off if it is not so set already.

￿Create a cable using the above diagram.

￿Attach the cableÕs DB9 connector end to PelcoNetÕs data port. Connect the cableÕs RJ-45 connector end to COM OUT on the back of the multiplexer.

￿Connect the MAIN video output from the multiplexer to the NET104A transmitter.

￿Connect PelcoNetÕs Ethernet port to the network using a Cat5 Ethernet patch cable.

C2900M-B (1/03)

91

Page 91
Image 91
Pelco C2900M-B(1/03 Connecting PelcoNet to Genex Using the COM in RS-232 Port, Create a cable using the above diagram