￿Connect a PV130 Converter to the RS-232 port on the front of the NET101R/R-A receiver. The data format should be 4800 baud, 8 data bits, no parity, and 1 stop bit.

￿Connect the black and white striped wire from the power supply that comes with the converter to the converterÕs +12 VDC terminal and the solid black wire to the GND terminal.

￿Connect RD(A) on the converter to terminal 2 on the wall block. Connect RD(B) on the converter to terminal 1 on the wall block.

￿Connect a 12 VAC power supply to terminals 3 and 4 on the wall block.

￿Set DIP switch 6 on the KBD300A to ON to enable turbo pan operation or OFF to disable that feature. The KBD300A will recognize Direct Mode automatically.

￿Connect the wall block to the KBD300A with an RJ-45 straight cable.

￿Connect the monitor.

￿Refer to Figures 38 and 39. Splice the supplied DB9 cable into the Spectra/Esprit or receiver cable. Use P protocol only.

To connect multiple Spectras/Esprits or receivers to the transmitter, daisy chain them in a series through the TX- and TX+ cable and attach the video cables to inputs 2 through 4.

￿Plug the supplied DB9 cable into the COM port on the transmitter. The data format should be 4800 baud, 8 data bits, no parity, and 1 stop bit.

￿￿Connect the cameraÕs video to the transmitter.

86

C2900M-B (1/03)

Page 86
Image 86
Pelco C2900M-B(1/03 manual C2900M-B 1/03