￿Connect a PV130 Converter to the RS-232 port on the front of the NET101R/R-A receiver. The data format must be 9600 baud, 8 data bits, odd parity, and 1 stop bit.

￿Connect the black and white striped wire from the power supply that comes with the converter to the converterÕs +12 VDC terminal and the solid black wire to the GND terminal.

￿Connect TD(A) on the converter to terminal 7 on the wall block. Connect TD(B) on the converter to terminal 8 on the wall block. Connect RD(A) on the converter to terminal 2 on the wall block. Connect RD(B) on the converter to terminal 1 on the wall block.

￿Connect a 12 VAC power supply to terminals 3 and 4 on the wall block.

￿Connect the wall block to the KBD4000 with an RJ-45 straight cable.

￿Connect the monitor.

￿Refer to Figures 38 and 40. Splice the supplied DB9 cable into the multiplexer wall block. Connect TX- from the NET104A to terminal 2 on the wall block, TX+ to terminal 1, RX- to terminal 7, and RX+ to terminal 8.

￿Plug the supplied DB9 cable into the COM port on the transmitter. The data format must be 9600, 8, odd, 1.

￿Connect the wall block to COM IN on the multiplexer with an RJ-45 straight cable.

￿￿Connect MAIN video output from the multiplexer to the transmitter.