Table F. Alarm Settings (Continued)

 

 

 

Receiver email

empty

If applicable, enter the e-mail address where you

address

 

want an e-mail sent in the event of an alarm.

 

 

 

Idle state

open

You can configure the switching behavior of each

 

 

built-in relay output at idle: open (N.O. at zero

 

 

current) or closed (N.C. at zero current).

 

 

 

Operating mode

Bistable

Select an operating mode for each relay.

 

 

¥ When you select the default Bistable mode, the

 

 

relay will stay in the idle or active state for an

 

 

indefinite period. (For example, select Bistable if

 

 

a floodlight activated by an alarm is to remain

 

 

switched on at the end of the alarm.)

 

 

¥ When you select Monostable mode, the relay

 

 

automatically falls back to the idle state after a

 

 

predefined period expires. (For example, select

 

 

Monostable 10s if a siren triggered by an alarm is

 

 

to sound for a period of 10 seconds.)

 

 

 

Relay follows

None

If necessary, select a particular event from the pull-

 

 

down menu that will trigger the relay. A typical

 

 

application is having the relay following the status of

 

 

the connection; for example, to power peripheral

 

 

equipment or even the camera itself. Select from the

 

 

following:

 

 

¥ Motion alarm: Triggering by motion alarm

 

 

¥ Input pin: Triggering by external alarm sensor

 

 

¥ Video loss: Triggering by video signal alarm

 

 

¥ Connection: Triggering at each connection setup

 

 

¥ Remote input pin: Triggering by switching

 

 

contact of the remote station

 

 

¥ None: No relay triggering by events

 

 

 

Relay Names

Relay 1-4

Assign a relay name to each output.

 

 

 

Trigger Relay

n/a

Clicking the appropriate Relay button switches that

 

 

relay by hand. Typical applications are opening

 

 

remote doors or operating lights.

 

 

 

C2900M-B (1/03)

59

Page 59
Image 59