ADIC/GRAU DAS and STK ACS Libraries

Troubleshooting Library Installation and ConfigurationTroubleshooting Library Installation andConfiguration

Installation Steps 1. Install the DAS Media Agent on the system controlling the GRAU robotics (PC/robot).

2.Install the DAS Media Agent on the NT PCs where a drive is connected (PC/drive).

3.Copy aci.dll + winrpc.dll + ezrpcw32.dll to winnt\system32 and <Data_Protector_home>\bin directory.

4.Create aci directory on PC/robot.

5.Copy dasadmin.exe to this directory.

6.Copy portmapper and portinst to aci directory.

7.Start portinst to install portmapper (only on PC/robot).

8.Install mmd patch on the CM.

9.The PC needs to be rebooted; then open Windows Control Panel. Go to Services (Windows NT) or Administrative Tools, Services

(other Windows systems) and check if portmapper and both rpc services are running.

10.Go to the OS/2 PC within the GRAU library, edit the

/das/etc/config file: cd /das/etc/ execute: "e config"

Within this config file you need to add a client called

DATA_PROTECTOR containing the IP address of the PC/robot.

11.Execute the following commands from PC/robot: dasadmin listd

dasadmin all DLT7000 UP <AMUCLIENT>

dasadmin mount <VOLSER> (then you need to push the UNLOAD button on the drive)

dasadmin dismount <VOLSER>

Chapter 14

697