Integrations with Other Applications

Access Points for System and Management Applications

To enable automatic forwarding of all Data Protector messages and messages about the Data Protector services (if they are stopped) to Windows Application Log, set the EventLogMessages variable in the Data Protector global options file to 1. For more information on Data Protector global options file refer to “Global Options File” on page 523.

Examples

Verifying Data Protector Processes

Data Protector provides a means of checking if its required processes are running by the means of the omnisv -statusCLI command.

The omnisv -statuscommand provides you with the status of the required Data Protector processes (when the command is started).

omnisv -statusTo get the status of required Data Protector processes enter the following command:

omnisv -status

Data Protector Health Check Failed Notification

The User Health Check notification is triggered and sent only if any of the required processes are not running or if the IDB is not operational. The Health Check Failed notification by default checks these conditions every day at 12:00 (Noon) and is (if the conditions are met), by default sent to Data Protector Event Log. You can change the scheduled time by changing the DailyMaintenanceTime variable, using the twenty-four hour clock notation, in the Data Protector global options file. For more information on Data Protector global options file refer to “Global Options File” on page 523. You can also redirect the notification to be sent, for example as an SNMP trap.

To check every day at the scheduled time if the required Data Protector processes are running and if the IDB is operational, and to be notified by an SNMP trap if any of the processes are not running or if database is not operational, configure the Health Check Failed notification as described in the “Data Protector Notifications” on page 342.

To check the conditions of the Health Check Failed notification interactively, enter the following command:

omnihealthcheck

Chapter 13

653

Page 683
Image 683
HP B6960-90078 manual Examples, Verifying Data Protector Processes, Data Protector Health Check Failed Notification