Integrations with Other Applications

MC/ServiceGuard Integration

/opt/omni/sbin/install/omniforsg.ksh -secondary /omni_shared

5.Unmount the mount point directory (Data Protector shared directory):

umount /omni_shared

6.Deactivate the volume group you imported: vgchange -a n /dev/vg_ob2cm

Configuring the Cell Manager Package

NOTE

The following section provides step-by-step examples to configure the

 

Data Protector package. Directory and file names, numbers, and other

 

variables will differ from the following examples according to your

 

environment. The cluster configuration file name cluster.conf and the

 

Data Protector package name ob2cl is used also as an example. You

 

should follow the names given to you by your network or domain

 

administrator.

 

Note that the Data Protector daemons are not running anymore on

 

 

either cluster node.

Prerequisites

• The Data Protector Cell Manager should be installed and configured

 

on both cluster nodes as explained in the previous section.

 

• Before configuring the Data Protector cluster package, you should

 

have a cluster configuration file created and edited.

Configuring Data On the Primary Cell Manager node proceed as follows:

Protector Package

1.Check the cluster configuration file for errors: cmcheckconf -C /etc/cmcluster/cluster.conf

If there are errors, fix them.

If there are no errors, enable the configuration: cmapplyconf -C /etc/cmcluster/cluster.conf

2.Start the cluster: cmruncl

Chapter 13

633

Page 663
Image 663
HP B6960-90078 manual Configuring the Cell Manager Package, Protector Package