Disaster Recovery

Preparing for a Disaster Recovery

corresponding media must be added to the SRD. The SRD can be updated only on a Windows client. The name of the updated SRD file is recovery.srd.

How to Update There are three different methods possible for updating the SRD file:

SRD?

Update SRD File Wizard

omnisrdupdate command as a standalone utility

omnisrdupdate command as a backup session post-exec script

Using SRD Update To update the SRD file using the Update SRD File Wizard:, proceed as

Wizardfollows:

1.In the Data Protector Manager switch to the Restore context and then click the Tasks Navigation tab.

2.In the Scoping Pane of the Tasks Navigation tab, check the

Disaster Recovery.

3.In the Results Area, check the SRD File Update option button, select the client and click Next.

4.For each of the critical objects, select an object version and click Next.

5.Type the destination directory where the updated SRD file is to be placed and click Finish.

IMPORTANT

Because the SRD file is saved on the Cell Manager system, it is not

 

accessible if the Cell Manager fails. As a result, you need an additional

 

copy of the Cell Manager’s SRD which should be stored in a vault.

 

In addition to the Cell Manager, you should save the updated SRD file to

 

several secure locations as a part of the disaster recovery preparation

 

policy. See “Preparation” on page 451.

 

 

Using

It is also possible to update the SRD file using the omnisrdupdate

omnisrdupdate

command as a standalone command. The omnisrdupdate command is

 

located in the <Data_Protector_home>\bin directory.