Further Information

Disaster Recovery: Move Kill Links on HP-UX 11.x

Disaster Recovery:

Move Kill Links on HP-UX 11.x

Proceed as shown below on the system which you want to back up to move some links:

#The system will go from "run-level" 4 to "run-level 1"

#retaining the inetd, networking, swagentd services up. The state is called "minimum activity" for backup purposes (need networking).

#IMPORTANT: ensure the links are present in /sbin/rc1.d before

#moving and they do have this exact name. You have to rename them for the rc0.d directory. Put them BELOW the lowest (original "/sbin/rc0.d/Kxx") "K...-link" in rc0.d

#Move K430dce K500inetd K660net K900swagentd into

../rc0.d BELOW the lowest kill link!!!

echo "may need to be modified for this system"

exit 1

#

cd /sbin/rc1.d

mv K430dce ../rc0.d/K109dce

mv K500inetd ../rc0.d/K110inetd

mv K660net ../rc0.d/K116net

mv K900swagentd ../rc0.d/K120swagentd

Appendix A

A-25

Page 755
Image 755
HP B6960-90078 manual Disaster Recovery Move Kill Links on HP-UX