Monitoring, Reporting, Notifications, and the Event Log

Data Protector Notifications

Windows NT

To configure Windows NT SNMP traps, proceed as follows:

 

1.

On the Cell Manager, open Control Panel, Network, Services. If

 

 

there is no SNMP Service entry in the list of network services under

 

 

the Services tab, perform step 2. If there is, skip step 2.

 

2.

Click Add and select SNMP Service. Click OK. Insert the Windows

 

 

NT installation CD, or provide an alternative path to the requested

 

 

files. Click Continue.

 

3.

Select SNMP Service and click Properties. Select the Traps tab

 

 

and enter public in the Community Name drop-down list. Click Add

 

 

next to the Community Name drop-down list.

 

4.

Click Add under Trap Destinations text box and enter the

 

 

hostname of the VPO Management Server. Click Add. Repeat this

 

 

step to add any number of VPO Management Servers.

 

5.

Click OK. Click Close.

 

6.

Start omnisnmp.

Windows

To configure Windows 2000/XP/Server 2003 SNMP traps, proceed as

2000/XP/Server

follows:

2003

1.

On the Cell Manager, open Settings, Network and Dial-up

 

 

 

Connections.

 

2.

In the Advanced menu, select Optional Networking Components

 

 

to start the wizard.

 

3.

In the wizard, select Management and Monitoring tools and click

 

 

Next.

 

4.

Follow the wizard to install the Management and Monitoring tools.

 

5.

Open Control Panel, Administrative Tools, Services.

 

6.

Right-click SNMP Service and select Properties.

 

 

a. Select the Traps tab and enter public in the Community name

 

 

text box and the hostname of the VPO Management Server in the

 

 

Trap Destinations text box.

b. Select the Security tab. Under Accepted community names,

select the community public, click Edit and set Community rights to READ CREATE.

c. Confirm your settings.

350

Chapter 7

Page 380
Image 380
HP B6960-90078 manual Windows NT, 350