Integrations with Other Applications

 

MC/ServiceGuard Integration

 

mount /dev/vg_ob2cm/lv_ob2cm /omni_shared

 

5. Modify the /etc/opt/omni/sg/sg.conf template file.

 

 

IMPORTANT

The SHARED_DISK_ROOT variable must contain the name of the mount

 

point directory (for example, SHARED_DISK_ROOT=/omni_shared).

 

The CS_SERVICE_HOSTNAME variable must contain the name of the

 

virtual Cell Manager, as it is known to the network. Each package in the

 

cluster requires its own virtual IP address and its network name (for

 

example, CS_SERVICE_HOSTNAME=ob2cl.company.com).

 

 

6.Configure the Primary Cell Manager. Make sure not to be positioned in the /etc/opt/omni/ or /var/opt/omni/ directory or their subdirectories when running the script. Make also sure to have no mounted subdirectories in the /etc/opt/omni/ or /var/opt/omni/. Run:

/opt/omni/sbin/install/omniforsg.ksh -primary

Note that after running this script, the Data Protector services are stopped and will be restarted later on.

7.Unmount the mount point directory (Data Protector shared directory):

umount /omni_shared

8.Deactivate the volume group you created: vgchange -a n /dev/vg_ob2cm

9.Export the volume group you created on the Primary Cell Manager with the following steps:

a.From system1 (Primary Cell Manager) export the LVM configuration information with map file /tmp/lvm_map:

vgexport -p -m /tmp/lvm_map /dev/vg_ob2cm

b.Transfer the map file over to system2 (Secondary Cell Manager): rcp /tmp/lvm_map second_system:/tmp/lvm_map

Configuring the To configure the secondary Cell Manager on system2, proceed as follows:

Secondary Cell

Manager

Chapter 13

631

Page 661
Image 661
HP B6960-90078 manual Secondary Cell Manager