HP B6960-90078 manual 636

Models: B6960-90078

1 856
Download 856 pages 1.47 Kb
Page 666
Image 666

Integrations with Other Applications

MC/ServiceGuard Integration

IMPORTANT

The service name must be the same as that used in the configuration file.

 

The service command (the SERVICE_CMD variable) must be the one used

 

in the example below.

 

 

For example:

 

 

 

 

SERVICE_NAME [0] = omni_sv

 

 

SERVICE_CMD [0] = “/etc/opt/omni/sg/csfailover.ksh start”

 

 

SERVICE_RESTART [0] = “-r 2”

 

 

To make sure that the Cell Manager package is restarted at

 

 

failover, set the SERVICE_RESTART parameter to -R(to restart the

 

 

service for an infinitive number of times; this is not recommended)

 

 

or to “-r<number of restarts>(to restart the service for

 

 

defined number of times).

 

9. Check and propagate the Data Protector cluster package files, with

 

the following steps:

 

a. Copy the package control file to other nodes within the cluster:

 

 

remsh system2 “mkdir /etc/cmcluster/ob2cl”

 

 

rcp /etc/cmcluster/ob2cl/ob2cl.cntl

 

 

system2:/etc/cmcluster/ob2cl/ob2cl.cntl

 

b. Enable the Data Protector shared disk as a cluster volume group

 

 

(created before) on all cluster nodes:

 

 

vgchange -c y /dev/vg_ob2cm

 

c.

Check the Data Protector package:

 

 

cmcheckconf -P /etc/cmcluster/ob2cl.conf

 

d. If the check was successful, add the Data Protector package:

 

 

cmapplyconf -P /etc/cmcluster/ob2cl.conf

 

e.

Start the package:

 

 

cmrunpkg ob2cl

The cluster should be configured and the Data Protector Cell

Manager package should be up and running.

636

Chapter 13

Page 666
Image 666