Disaster Recovery

 

Manual Disaster Recovery of an HP-UX Client

 

core.cfg to archive_<name>.cfg:

 

cp /opt/ignite/data/examples/core.cfg

 

/var/opt/ignite/data/<OS_Release>/archive_<name>.cfg

Example

cp /opt/ignite/data/examples/core.cfg

 

/var/opt/ignite/data/Rel_B.11.11/archive_HPUX11_11_DP50_C

 

L.cfg

 

5. Check and change the following parameters in the copied

 

configuration file:

 

• In the sw_source section:

 

load_order = 0

 

source_format = archive

 

source_type="NET"

 

# change_media=FALSE

 

post_load_script = "/opt/ignite/data/scripts/os_arch_post_l"

 

post_config_script =

 

"/opt/ignite/data/scripts/os_arch_post_c"

 

nfs_source = "<IP Target System>:<Full Path>”

 

• In the matching OS archive section:

 

archive_path = "<archive_name>.gz

 

6. Determine the “impacts” entries by running the command

 

archive_impact on your image file and copy the output in the same

 

“OS archive” section of your configuration file:

 

/opt/ignite/lbin/archive_impact –t –g

 

<archive_name>.gz

Example

/opt/ignite/lbin/archive_impact –t –g

 

/image/archive_HPUX11_11_DP50_CL.gz

 

impacts = "/" 506Kb

 

impacts = "/.root" 32Kb

 

impacts = "/dev" 12Kb

 

impacts = "/etc" 26275Kb

 

impacts = "/opt" 827022Kb

 

impacts = "/sbin" 35124Kb

500

Chapter 10

Page 530
Image 530
HP B6960-90078 manual Swsource section, 500