Troubleshooting

Troubleshooting the IDB

 

Upgrade of detail part running.

 

 

The detail upgrade was started and is currently running.

 

Upgrade of detail part finished.

 

 

The detail upgrade finished.

 

The Cell Manager crashes during the core upgrade

 

The following methods can help you to identify the problem:

 

The omnidbutil –upgrade_infocommand on the Cell Manager

 

 

reports Core upgrade failed.

 

The upgrade.log file on the Cell Manager contains the UCP session

 

 

started entry but does not contain either the UCP session

 

 

finished nor the Session was aborted (Upgrade core part)

 

 

entry.

Action

1.

Run /opt/omni/sbin/omnisv -status to check whether the Data

 

 

Protector services are running on the Cell Manager. If they are not

 

 

running, start them using the /opt/omni/sbin/omnisv - start

 

 

command.

 

2.

Run the omnidbinit command on the Cell Manager to initialize the

 

 

new database. The A.03.51 IDB is set to read-only mode and is

 

 

therefore left intact.

 

3.

Run the omnidbupgrade -ucpcommand to restart the core upgrade.

 

4.

When the core upgrade is finished, continue with the detail part

 

 

upgrade.

The core upgrade runs out of disk space

The upgrade.log file on the Cell Manager contains the Not enough disk space or not enough configure extension/binary files to perform upgrade entry after the UCP session started entry. Refer to the HP OpenView Storage Data Protector Software Release Notes for disk space requirements.

Action

1.

Free up disk space on the system where the IDB is installed.

 

2.

Run the omnidbinit command to initialize the new database. The

 

 

A.03.51 IDB is set to read-only mode and is therefore left intact.

 

3.

Restart the core upgrade using the omnidbupgrade –ucpcommand.

Chapter 12

593