Customizing the Data Protector Environment

Firewall Support

Firewall Support

This section describes how to configure Data Protector in an environment where the Data Protector processes communicate across a firewall.

Communication in Data Protector processes communicate using TCP/IP connections. Every

Data Protector

Data Protector system accepts connections on port 5555 by default. In

 

addition, some processes dynamically allocate ports on which they accept

 

connections from other Data Protector processes.

 

To enable Data Protector processes to communicate across a firewall,

 

Data Protector allows you to limit the range of port numbers from which

 

dynamically allocated ports are selected. Port ranges are defined on a per

 

system basis. It is possible to define a port range for all Data Protector

 

processes on a specific system, as well as to define a port range for a

 

specific Data Protector agent only.

Configuration

The port allocation behavior can be configured through two omnirc

Mechanism

variables: OB2PORTRANGE and OB2PORTRANGESPEC. By default, both

 

variables are not set and ports are assigned dynamically by the

 

operating system.

 

Limiting the Range of Port Numbers

For All Data

You can limit the port range for all Data Protector processes on a system

Protector

by using the OB2PORTRANGE variable in the omnirc file:

Processes

OB2PORTRANGE=<start_port>-<end_port>

 

 

Data Protector processes use dynamically allocated ports and select

 

ports from this range. The port range is allocated by taking the first

 

available port, starting with port "start_port". If there is no available

 

port within the specified range, the port allocation fails and the

 

requested operation is not done. Refer to Table 11-1 on page 530 for

 

information on port consumption.

528

Chapter 11

Page 558
Image 558