JVC SR-9240EK Others Input data correction/Error cancellation, Commands reference chart

Models: SR-9240EK SR-9240E

1 55
Download 55 pages 47.05 Kb
Page 51
Image 51

10. OPTIONAL SA-K97U RS-232C INTERFACE BOARD

2-4 Others (Input data correction/Error cancellation)

These are return codes from the SR-9240E/EK. (Error-related codes only)

(1)ERROR (02H) : This is returned when commands of more than 1 byte are transmitted to the VCR and an illegal command is received in the 2nd byte (or later) of the transmitted command.

In this status, no command can be accepted and only STATUS SENSE will be returned. To restore normal operation, transmit CLEAR ERROR (41H) or CLEAR (56H) to the VCR.

CLEAR ERROR (41H) : Used to cancel previously-transmitted 1-byte numeric data when inputting

 

numeric data such as an Index search point. Also used to cancel error status.

 

 

CLEAR (56H)

: Clears the whole command. Cancels the current status and stops the VCR. Also

 

cancels the error status.

Eg : After setting the recording/playback mode to “L24H”, 32H is mistakenly transmitted . Cancel 32H with “41H” and input “33H” instead.

TXD

7EH

 

 

 

30H

 

 

 

32H

 

 

 

41H

 

 

 

33H

 

 

 

40H

 

 

RXD

0AH

 

0AH

 

 

 

0AH

 

 

 

0AH

 

 

 

0AH

 

 

 

0AH

Time

(2) NAK (0BH)

: VCR will return this code when non-defined or non-functional command is received in the 1st byte of the

 

transmitted command. In this case, it is not necessary to input CLEAR. Check whether the transmitted command

 

is acceptable to the VCR or not.

3 Commands reference chart

VCR control commands

 

Page

 

 

OPERATE ON/OFF

47

PLAY/REV PLAY

47

STOP

47

FF/REW

47

TIMER ON/OFF

47

OPE ON/OFF

47

EJECT

47

F-FIELD STEP

47

REC CHECK

47

 

 

REC/REC PAUSE

47

VISS FWD/REV

47

VISS SEARCH

48

Commands for VCR status verification

 

Page

Byte returned

 

 

from VCR

 

 

 

COUNT CODE

50

4 bytes

DEVICE TYPE

50

4 bytes

VTR INQ

50

1 byte

PL/AL COUNT SENSE

50

6 bytes

HOUR METER SENSE

50

5 bytes

TL STATUS SENSE

50

6 bytes

 

 

 

STATUS SENSE

51

5 bytes

 

 

 

DATA SENSE

50

6 bytes

 

 

 

TIME SENSE

50

6 bytes

 

 

 

VCR setting commands

 

Page

 

 

5Recording/playback mode

48

MODE SHIFT

48

MODE

48

 

 

5Timelapse VCR operation mode

48

TL STATUS

48

5Date and time setting

49

DATE SET

49

TIME SET

49

 

 

5Timer programming

49

PRG

49

SHIFT –/+

49

SET –/+

49

CANCEL

49

 

 

5On-screen setting

49

ON SCREEN ON/OFF

49

ON SCREEN SELECT

49

5Others

49

AL/PL RESET

49

COUNT RESET

49

 

 

 

 

Return codes from VCR

 

 

 

 

Page

 

 

ACK

47

NAK

52

ERROR

52

CASSETTE OUT

47

COMPLETION

47

NOT TARGET

47

ALARM INPUT

51

 

 

 

 

Others

 

 

 

 

Page

 

 

JVC TABLE 1 ON/OFF

47

 

 

52

Page 51
Image 51
JVC SR-9240EK appendix Others Input data correction/Error cancellation, Commands reference chart