11 APPENDIXES

11-2 Rear Panel’s Input/Output

[CAM SW OUT] camera switching signal output

The CAM SW OUT terminal outputs a camera switching timing signal to the connected sequential switcher. The switching interval can be set with the <CAM SW> on the VTR mode 1 setting screen. The camera switching signal is output at ground level.

Camera

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switching

During recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signal output

 

 

 

 

 

 

 

 

 

 

 

 

1 field

 

 

 

 

 

timing

During standby

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With the <CAM SW>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

5m sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

function menu switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

set to "1 FIELD"

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timelapse recording

Camera switching signal (open-collector output)

Other input/output terminal signal levels

Terminals

 

 

 

 

 

 

 

 

 

Signal levels

 

 

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input at ground level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm signal input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LV: 0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 400 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM RST IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HV: 5 V ~ 12 V

 

 

Input at high level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm signal reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 400 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM REC OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HV:12 V

 

 

Output at high level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(output impedance: 4.7 kohms)

 

mode signal output

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Record mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAPE END OUT

Record mode:

 

 

 

 

 

 

 

 

 

Record mode:

 

 

Output at ground level

repeat recording ON/auto rewind ON

repeat recording OFF/auto rewind OFF

Tape end signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output

 

 

 

 

 

 

LV: 0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

About 2

 

Max. 10 mA

 

 

Tape end

 

Manual

 

 

 

 

 

 

seconds

 

 

 

 

 

 

 

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING/REC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HV: 12 V

 

 

Output at high level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(output impedance: 4.7 kohms)

 

Warning signal/Rec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode signal output

 

 

 

 

 

Warning

 

 

 

Warning reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOCK RESET IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input at ground level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock reset input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LV: 0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 150 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOCK RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output at ground level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock reset output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LV: 0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

About 150 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 