7 RECORDING

7-6 Repeat Recording

When the tape reaches the end during recording, it is automatically rewound and recording starts again from the beginning.

5To execute repeat recording, set <TAPE END MODE> on the VTR mode 1 setting screen to REPEAT.

5Setting the function menu switch <TAPE END MODE> on the alarm/sensor recording mode setting screen

When the tape ends during recording in the case when alarm or sensor recording is executed even once, the tape stops or rewinds and stops at the beginning if this menu switch set to “STOP” or “REW”,.

If this menu switch is set to "EJECT", the tape is ejected.

 

 

 

 

VTR MODE 1

 

Auto recording

 

(SHARPNESS)

NORMAL

 

(VIDEO MODE)

AUTO

check function

 

 

(AUTO REC)

OFF

Tape end mode

 

 

 

(REC CHECK)

AUTO

 

 

 

(TAPE END MODE)

REPEAT

 

 

 

 

 

 

(INDEX SEARCH)

OFF

 

 

 

 

(CAMERA SW)

OFF

 

 

 

 

(TAPE END BUZZER)

OFF

 

 

 

 

(WARNING BUZZER)

OFF

PRESS (SHIFT, SET)

PRESS (MENU) TO END

VTR mode 1 setting screen

Set to

REPEAT

To continue repeat recording even when alarm/ sensor recording is executed, set this menu switch to “REPEAT” .

Auto Recording Check function

This function automatically checks recording quality at the beginning of the tape during repeat recording.

To activate the Auto Recording Check function, set the <REC CHECK> function menu switch in the VTR mode 1 setting screen to AUTO.

Operation of the Auto Recording Check function

The recorded section at the beginning of the tape is automatically played back in the Repeat Record mode and the FM level recorded on the tape is checked. If the level is satisfactory, recording continues.

If recording quality is deemed inferior, the heads are cleaned automatically. After several seconds of recording, the recording state is checked again.

If recording quality is still unsatisfactory after two consecutive checks, the error indicator E-09 is shown in the display and recording continues.

*When repeat recording is performed, the previously- recorded alarm recording is erased.

Function menu switch <REC CHECK> set to AUTO

Repeat recording

 

 

 

 

 

 

 

 

 

 

 

 

 

Beginning of

Recording

 

Normal

 

Recording

 

 

the tape

check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto head

 

 

 

 

 

 

 

 

 

 

cleaning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recording

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto recording

 

 

Recording

 

 

 

 

 

 

 

 

 

 

for several

 

check

 

 

 

 

 

 

seconds

 

 

Defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto head

 

Recording

 

 

 

 

 

 

 

 

 

cleaning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error indicator E-09 display

 

 

36

Page 35
Image 35
JVC SR-9240EK appendix Repeat Recording, Check function