CS14, CSN14 Series Converter Switches

Installation and User Guide (02/06)

Operating Environment

 

CS14, CSN14:

32ºF to 104ºF (0ºC to 40ºC)

CS14H, CSN14H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).

 

-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests.

CS14P, CSN14P:

-40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).

 

-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.

Storage Temperature,

All models:

-40ºF to 160ºF (-40ºC to 85ºC)

Cold Start:

 

CS14H, CSN14H to -20ºC

CS14P, CSN14P

to -40ºC

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude (All models):

-200 to 5000ft. (-60 – 15,000 m)

Conformal Coating (optional) for humidity protection

Note: H and P models are designed for NEBS compliance, including, vibration, shock and altitude.

www . GarrettCom . com

3

Page 10
Image 10
GarrettCom CSN14, CS14 manual Operating Environment, Storage Temperature, Cold Start