CS14, CSN14 Series Converter Switches

Installation and User Guide (02/06)

fiber port 10BASE-FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.

Media

IEEE Standard

Connector

Twisted Pair (CAT 3 or 5)

10BASE-T

RJ-45

Twisted Pair (CAT 5)

100BASE-TX

RJ-45

Fiber (Multi-mode, Single -mode)

10BASE-FL

ST

Fiber (Multi-mode)

100BASE-FX

ST, SC

Fiber (Single-mode)

100BASE-FX

SC, LC

Fiber (Multi-mode)

100BASE-FX

MTRJ

NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps and 100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since P80-series switch ports are auto-sensing for either 10 and 100Mbps. Note that the auto-cross function does not operate, if the port is fixed or not supporting auto-negotiation.