GarrettCom CS14, CSN14 manual 100BASE-TX CAT 5 UTP, Maximum Ethernet Segment or Domain Lengths

Models: CS14 CSN14

1 76
Download 76 pages 5.24 Kb
Page 9
Image 9

CS14, CSN14 Series Converter Switches

Installation and User Guide (02/06)

Address buffer age-out time: 300 sec.

Packet buffers memory: 128KB, dynamically shared on all domains

Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 15µs

Path Delay Value: 50 BT on all ports

Maximum Ethernet Segment (or Domain) Lengths

 

10BASE-T (Unshielded twisted pair)

- 100 m (328 ft)

100BASE-TX (CAT 5 UTP)

- 100 m (328 ft)

100BASE-FX, half-duplex: (multi-mode)

- 412 m (1350 ft)

100BASE-FX, full-duplex: (multi-mode)

- 2 km (6,562 ft)

100BASE-FX, half-duplex: (single-mode)

- 412 m (1350 ft)

100BASE-FX, full-duplex: (single-mode)

- 20 km (65,620 ft)

100BASE-FX, full-duplex: (single-mode, long reach)

- 40 km (131,240 ft)

10BASE-FL, Fiber optic

- 2 km (6,562 ft)

10BASE-FL, Single-mode Fiber optic

- 10 km (32,810ft)