Event ID  Event Description  Signal Type 
1 S-RING OPEN  SUSTAINED 
2 Cold Start  MOMENTARY 
3 Warm Start  MOMENTARY 
4 Link Up  MOMENTARY 
5 Link Down  MOMENTARY 
6 Authentication Failure  MOMENTARY 
7  RMON Rising Alarm9 MOMENTARY 
8  RMON Falling Alarm  MOMENTARY 
9 Intruder Alarm  MOMENTARY 
10   Link Loss Learn Triggered              MOMENTARY 
11  Broadcast Storm Detected  MOMENTARY 
12 STP/RSTP Reconfigured MOMENTARY 
FIGURE 136 – Predefined conditions for the relay 
The S-RING open condition generates a sustained relay contact close. The relay will stay closed 
during the period which the S-RING is in OPEN condition. The relay will revert to closed 
position when the S-RING goes to CLOSED position. This information is covered in more 
details in Chapter 11 on S-Ring and Link-Loss-Learn.  
To customize these capabilities, the MNS-6K provides additional software capabilities and 
commands for configuring the behavior. They are 
Syntax alarm – enter the alarm configuration mode 
Syntax add event=<event-id|list|range|all> - enables alarm action in response to the specified event ID 
9  The RMON settings are when the RMON thresholds are crossed and hence indicated as RMON rising or falling – indicating the 
threshold has been crossed . While there is no specific command to view and change the specific RMON variables, the RMON 
discussion is in Chapter 16. Best way to set RMON values will be via using the web interface or a Management system such as 
Castle Rock’s SNMPc™