10 Multilink Firmware Updates

10.1 Updating MultiLink Firmware

This section describesthe process for upgrading the firmware on a GE Multilink Ethernet switch. The methods describe updating the Multilink firmware either locally using the console port or remotely over the network using FTP or TFTP.

The following equipment and software are required for loading the Multilink Ethernet switch with the new firmware version.

1.A female-to-female null modem cable. (This is only necessary when upgrading using the Multilink console port.)

2.PC serial port. If your PC does not have a serial port, a USB-to-serial converter will be required. (This is only necessary when upgrading using the Multilink console port.)

3.A PC (or a workstation/computer) with a terminal emulation program such as Huyperterminal (included with Windows) or Teraterm-pro or other equivalent software. Verify that the software supports Xmodem protocol.

4.Enough disk space to store and retrieve the configuration files as well as a copy of the Multilink firmware. We recommend at least 15 MB of free disk space.

5.Manager level account name and password for the switch being upgraded.

6.An internet connection. Ensure the connection does not block ftp file transfers

10.2Selecting the Proper Version

The latest version of the firmware is available at:

http://www.GEmultilin.com/catalog/ethernet.htm.

To deternine the version of firmware currently installed on your switch, do the following:

ZUsing the command line interface, log into the switch uwing Manager access rights.

ZIn the command line prompt, enter the command, show version.

ZUsing the EnerVista web interface, enter the IP address of the switch in the address bar of a web browser

The firmware version installed on the switch will appear in the lower left corner of the screen.

10.3Upgrading Using a Serial Connection- Command Line Interface

Use the following procedure to install firmware to the MultiLink Ethernet Switch via the serial port.

ZDownload the MultiLink Switch Software from the GE Multilin web site, to a convenient location on your hard drive.

ZUse the null-modem cable to connect to the serial port of the switch.

ZLogin at the manager level with the proper password.

MULTILINK ETHERNET COMMUNICATIONS SWITCH – QUICKSTART GUIDE

57

Page 61
Image 61
GE 1601-9026-A3 quick start Multilink Firmware Updates, Updating MultiLink Firmware, Selecting the Proper Version

1601-9026-A3 specifications

The GE 1601-9026-A3 is a sophisticated and versatile unit that has garnered attention in various industrial applications due to its reliability and advanced features. This product, part of the GEs extensive range of control systems, is designed to meet the needs of modern industries, promoting efficiency and performance.

One of the main features of the GE 1601-9026-A3 is its robust architecture, which ensures high availability and redundancy. This design minimizes downtime and enhances operational continuity, a critical requirement for industries that rely on continuous processes. The unit incorporates state-of-the-art processing capabilities that enable it to handle complex computations and large datasets with ease.

A significant characteristic of the GE 1601-9026-A3 is its advanced communication protocols. It supports various industrial communication standards, including Ethernet, Modbus, and TCP/IP, making it highly compatible with existing infrastructure. This interoperability allows for seamless integration into diverse systems, facilitating data exchange and real-time monitoring.

The device also features an intuitive user interface, allowing operators to navigate easily through its functionalities. The graphical display often includes real-time data visualization tools, enhancing operators' ability to monitor system performance and respond promptly to any anomalies. This user-centric design contributes to reduced training time and improved operational efficiency.

In terms of technologies, the GE 1601-9026-A3 incorporates cutting-edge automation features, including programmable logic controllers (PLCs) and advanced algorithms for predictive maintenance. These technologies help in preemptively identifying potential issues before they escalate, reducing maintenance costs and enhancing equipment lifespan.

Moreover, the unit is designed with a focus on energy efficiency, featuring intelligent energy management systems that optimize power consumption. This not only contributes to cost savings but also aids in reducing the environmental footprint of industrial operations.

Durability is another characteristic that stands out with the GE 1601-9026-A3. Built to withstand harsh industrial environments, this unit is resistant to temperature fluctuations, dust, and moisture, ensuring reliable performance in demanding conditions.

In summary, the GE 1601-9026-A3 exemplifies cutting-edge technology fused with practicality, offering a range of features designed to enhance operational efficiency, reliability, and ease of use. Its advanced communication capabilities, durability, and focus on energy efficiency make it a prime choice for industries looking to modernize their control systems.