GE 17, 16 1INSTALLING THE WATER LINE CONT, 7CONNECT THE TUBING TO THE REFRIGERATOR

Models: 16 17

1 24
Download 24 pages 52.76 Kb
Page 12
Image 12
1INSTALLING THE WATER LINE (CONT.)

Installation Instructions

1INSTALLING THE WATER LINE (CONT.)

7CONNECT THE TUBING TO THE REFRIGERATOR

NOTES:

‡%HIRUHPDNLQJWKHFRQQHFWLRQWRWKHUHIULJHUDWRUEH sure the refrigerator power cord is not plugged into the wall outlet.

‡:HUHFRPPHQGLQVWDOOLQJDZDWHU¿OWHULI\RXUZDWHU supply has sand or particles that could clog the screen

RIWKHUHIULJHUDWRU·VZDWHUYDOYH,QVWDOOLWLQWKHZDWHU line near the refrigerator. If using GE SmartConnect

5HIULJHUDWRU7XELQJNLW\RXZLOOQHHGDQDGGLWLRQDOWXEH :;; WRFRQQHFWWKH¿OWHU'RQRWFXWSODVWLF WXEHWRLQVWDOO¿OWHU

Remove the access cover.

5HPRYHWKHSODVWLFÀH[LEOH cap from the water valve

UHIULJHUDWRUFRQQHFWLRQ 

3ODFHWKHFRPSUHVVLRQQXWDQGIHUUXOH VOHHYH RQWR WKHHQGRIWKHWXELQJDVVKRZQ2Q*(6PDUW&RQQHFW5HIULJHUDWRU7XELQJNLWWKHQXWVDUHDOUHDG\DVVHPEOHG WRWKHWXELQJ

,QVHUWWKHHQGRIWKHWXELQJLQWRWKHZDWHUYDOYH FRQQHFWLRQDVIDUDVSRVVLEOH:KLOHKROGLQJWKHWXELQJ WLJKWHQWKH¿WWLQJ

)RUSODVWLFWXELQJIURPD*(6PDUW&RQQHFW5HIULJHUDWRU7XELQJNLWLQVHUWWKHPROGHGHQGRIWKH

WXELQJLQWRWKHVKXWRȺYDOYHDQGWLJKWHQFRPSUHVVLRQ nut until it is hand tight, then tighten one additional turn with a wrench. Overtightening may cause leaks.

)DVWHQWKHWXELQJLQWRWKHFODPSSURYLGHGWRKROGLWLQD vertical position. You may need to pry open the clamp.

8TURN THE WATER

ON AT THE

SHUTOFF VALVE

Tighten any connections that leak.

9INSTALLING THE REFRIGERATOR

Plug in the refrigerator.

$UUDQJHWKHFRLORIWXELQJVR

WKDWLWGRHVQRWYLEUDWHDJDLQVW

WKHEDFNRIWKHUHIULJHUDWRU or against the wall. Push the

UHIULJHUDWRUEDFNWRWKHZDOO

10 START THE ICEMAKER

On power switch models, set the icemaker power switch to the 0N position. On feeler arm models, move the feeler arm to the ON GRZQ SRVLWLRQ7KH

LFHPDNHUZLOOQRWEHJLQWRRSHUDWHXQWLOLWUHDFKHVLWV RSHUDWLQJWHPSHUDWXUHRIƒ) ²ƒ& RUEHORZ,WZLOO

WKHQEHJLQRSHUDWLRQDXWRPDWLFDOO\

Power 7CONNECT THE TUBING TO THE REFRIGERATOR8TURN THE WATER9INSTALLING THE REFRIGERATOR10 START THE ICEMAKER switch Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

ON OFF

1/4Copper

7XELQJ

Refrigerator Connection

7XELQJ Clamp

1/4Compression

Nut

Ferrule

VOHHYH

SmartConnect

7XELQJ

Power switch model

Manual background Feeler Arm in the

STOP XS SRVLWLRQ

Manual background Feeler Arm in

Reattach the access cover.

12

the ON GRZQ SRVLWLRQ

Feeler arm model

NOTE: In lower water pressure conditions, the water valve may turn on up to 3 times to deliver enough water to the icemaker.