GE 2800 manual Zoneline Features

Models: 2800

1 60
Download 60 pages 2.9 Kb
Page 8
Image 8
Zoneline® Features

Zoneline® Features

 

 

AZ

AZ

AZ

 

 

2800

800

5800

Enhanced Dehumidification — Dry Air 25

Optional

N/A

N/A

Cooling EER Range (230 Volts/265 Volts)

10.2 - 12.7

10.0 - 12.7

10.2 - 13.0

Heating COP Range (230 Volts/265 Volts)

N/A

.2 - 3.6

.2 - 3.6

Heat Source — Electric Resistance Heat

Standard

Heat Source — Heat Pump With Selectable

 

 

 

 

Full Time or On Demand Simultaneous/

 

 

 

 

Supplemental Resistance Heat

Standard

Standard

Staged Heating

 Stage

 Stage

Universal Heater — UPC*

Standard

Standard

Standard

Unit Controls

Rotary Knobs

Rotary Knobs

Touch Pad

Electronic Temperature Selection

 

 

 

(Slews Up & Down) with Digital Display

Standard

 

 

 

 

Unit Diagnostics

Standard

Highly Featured Microprocessor Controls

Standard

Standard

Standard-Plus

Electric Resistance Heat Lock-Out (above 46°F)

Standard

Standard

Automatic Emergency Heat

Standard

Standard

Heat Pump Defrost System

Reverse Cycle

Reverse Cycle

High Temperature Operation Protection

Standard

Standard

Quick Heat Recovery

Standard

Standard

Temperature Boost

 

Selectable

Selectable

Service Indicator

Temp Display Blinks

Fan Motors — Permanently Lubricated

2

2

2

2-Speed Outdoor Fan

Standard

Standard

Standard

Indoor Fan Speed Selections — HIGH/LOW

Standard

Standard

HIGH/LOW/AUTO

Fan Only Setting — HIGH/LOW

Standard

Standard

Standard

Fan Cycle Switch

“Smart Fan”

“Smart Fan”

“Smart Fan”

Constant-Run Fan

Selectable

Selectable

Selectable

Rotary Compressor

Standard

Standard

Standard

Automatic Compressor Restart Delay

Standard

Standard

Standard

Freeze Sentinel

Standard

Standard

Standard

 

 

 

 

Heat Sentinel

Standard

Standard

Standard

Indoor Coil Frost Control

Standard

Standard

Standard

Transfer Fan Connections

Standard

Standard

Standard

7-Step Electronic Temperature Limiting

Standard

Standard

Standard

Remote Control Capability with Wall Mounted Thermostat

Standard

Standard

Standard

Central Desk Control Capability

Standard

Standard

Standard

Energy Management System Interface with Load Shedding Option

Standard

Standard

Standard

Reversible Indoor Air Louvers 40º/50º

Standard

Standard

Standard

Up-Front Filters

Standard

Standard

Standard

Easy-Clean Air Discharge Area

Standard

Standard

Concealed Manual Vent Control

Standard

Standard

Standard

Ducted Installation Capability

RAK6052

RAK6052

Corrosion Protection (Standard on Dry Air 25)

Optional

Optional

Standard

Internal Condensate Removal (ICR) (Factory Installed Option.

 

 

 

Cannot be used in Corrosion Areas.)

N/A

Optional

Optional

*UPC — Universal Power Cord Connection (See pages 42 and 55).

265-volt units must be connected in a manner to meet National Electrical Code and all local codes.

Page 8