GE 60-639-43-EUR-OD, 60-639-95R-OD manual Use the following procedure to mount the sensor

Models: 60-639-95R 60-639-43-EUR 60-639-43-EUR-OD 60-639-95R-OD

1 8
Download 8 pages 45.1 Kb
Page 3
Image 3
Use the following procedure to mount the sensor.

Flush Mount

Inclined Mount

 

Corner Mount

Swivel Mount

Note

The wall-tamper switch can- not be used when the sensor is swivel or corner mounted.

Figure 5. Wall Mounting Options

Use the following procedure to mount the sensor.

1.Remove the mounting plate by depressing the button on the top of the sensor body. With the opposite hand pull the mounting plate away from the body of the sensor.

2.Punch out the mounting holes that best fit your application. See Figure 5 for wall mount options. See Figure 6 to determine which knockouts to use when mounting the motion sensor. Use the lower-side holes for corner mounting, or the lower-back holes for surface mounting with the standard lens.

3.For applications with pets, use the upper mounting holes and the optional animal alley lens.

4.If you desire wall-tamper functionality, remove the wall-tamper knockout (see Figure 6).

Use With Animal

Alley Lens

Wall

Tamper

Manual backgroundKnockout

Use With

Standard Lens

Figure 6. PIR Mounting Plate Knockouts

5.Mark the location of the required holes on the mounting surface.

6.Use wall anchors and screws to secure into place. Attach the sensor to the mounting plate.

7.When testing is completed the PIR can be securely attached to its mounting plate by screwing the smallest enclosed screw into the hole at the top of the mounting plate.