GE AEW06, AET05 Window Requirements, 2STORM WINDOW REQUIREMENTS, 3PREPARE THE AIR CONDITIONER

Models: AEW05 AEW06 AEW08 AET05

1 28
Download 28 pages 10.74 Kb
Page 10
Image 10
WINDOW REQUIREMENTS

Installation Instructions

1

WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

Follow the dimensions in the table and illustration for your model.

Models

 

A

B

C

AET05, AEW05

13

1/4min.

22–38

18 1/4min.

AEW06, AEW08

14

1/2min.

23–38

19min.

 

 

 

 

 

A

B

(With accordion panels)

C

(Without accordion panels)

2STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the stool.

WOOD PIECES–

WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Wood

1/2higher

 

than frame

Stool

 

Storm

 

window

 

frame

 

3PREPARE THE AIR CONDITIONER

AInstall the top mounting rail with 2 Type B screws from the outside of the case.

Top mounting rail

Bottom mounting rail

BSlide the left and right accordion panels into the top and bottom mounting rails.

Top right

Top left

10

Page 10
Image 10
GE AEW06, AET05 Window Requirements, 2STORM WINDOW REQUIREMENTS, 3PREPARE THE AIR CONDITIONER, Installation Instructions