0150-0238A 6-1 Calibur DSR-1000eZ
6 RS-232 REMOTE PROTOCOL
The RS-232 protocol command structure uses “Start of Text” (Sx) and “End of Text” (Ex) characters to
identify the beginning and end of command sequences.
The DSR-1000eZ supports the following command sequences:

ASCII Command String

Command ASCII String Bytes in Hexadecimal
Play Forward Sx PLF Ex 02 46 50 4C 03
Record Sx REC Ex 02 52 45 43 03
Stop Sx STO Ex 02 53 54 4F 03
Pause Sx PAU Ex 02 50 41 55 03
Fast Forward Sx FWD Ex 02 46 57 44 03
Rewind Sx REW Ex 02 52 45 57 03
Frame Forward Sx FAD Ex 02 46 41 44 03
Frame Reverse Sx RAD Ex 02 52 41 44 03
Play Reverse Sx RPL Ex 02 52 50 4C 03
Increase Speed Sx ISP Ex 02 49 53 50 03
Decrease Speed Sx DSP Ex 02 44 53 50 03
Search Sx SEA Ex 02 53 45 41 03
Up Arrow Sx ARU Ex 02 41 52 55 03
Down Arrow Sx ARD Ex 02 41 52 44 03
Left Arrow Sx ARL Ex 02 41 52 4C 03
Right Arrow Sx ARR Ex 02 41 52 52 03
Menu Sx MEN Ex 02 4D 45 4E 03
Enter Sx ENT Ex 02 45 4E 54 03
Set Clock See instructions for setting clock in the following section.
Note: All byte values shown in hexadecimal.

NOTE