CPC Logic

One of the enhancements recently introduced by GE Energy is the Corrected Parameter Control logic (CPC). This type of control philosophy applies principally to mechanical drive units, and consists of an exhaust temperature control curve that self adjusts according to the condition of the inlet filters and actual power turbine speed. This allows the engine to be operated at optimum conditions not only at the nominal point, but over the entire operating envelop of inlet conditions and power turbine speeds. The results of this improvement have already been proven in the field, as shown in the following figure (relating to the test of a GE10-2 unit at various free power turbine speeds). Thanks to the application of CPC logic it has been possible to significantly increase the maximum output without compromising the safe operation of the unit by simply optimizing its operation in real-time.

The variable free power turbine speed element of the CPC logic is provided as standard on the GE5-2, MS5002D DLN and MS5002E models, and on all new GE10-2 units. The possibility to retrofit existing gas turbine models with this solution is also offered.

 

Ambient Temperature 22°C

 

 

 

 

102

 

 

 

 

 

 

 

101

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

99

CPC Control Logic

 

 

 

 

 

98

 

 

 

 

 

 

(%)

97

 

 

 

 

 

 

96

 

 

Old Control Logic

 

 

Power

95

 

 

 

 

94

 

 

 

 

 

 

93

 

 

 

 

 

 

Shaft

92

 

 

 

 

 

 

91

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

80

85

90

95

100

105

Power Turbine Speed (%)

21 GE Energy Gas Turbines

Page 21
Image 21
GE Gas Turbine manual CPC Logic, Ambient Temperature 22 C