Instructions

Care and cleaning of the water heater.

Draining the Water Heater

Installation Instructions Safety

CAUTION: Shut off power to the water heater before draining water.

DANGER: Before manually operating the relief valve, make certain no one will be exposed to the hot water released by the valve. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage.

In order to drain the water heater, turn off the cold water supply. Open a hot water faucet or lift the handle on the relief valve to admit air to the tank.

Attach a garden hose to the drain valve on the water heater and direct the stream of water to a drain. Open the valve.

Vacation and Extended Shut-Down

Operating Instructions

NOTICE: Refer to the Hydrogen Gas Caution in the Operating Instructions.

If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas.

The water heater and piping should be drained if they might be subjected to freezing temperatures.

After a long shut-down period, the water heater’s operation and controls should be checked by qualified service personnel. Make certain the water heater is completely filled again before placing it in operation.

Routine Preventative Maintenance

Customer Service Troubleshooting Tips Care and Cleaning

DANGER: Before manually operating the relief valve, make certain no one will be exposed to the danger of coming in contact with the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage.

NOTICE: If the temperature and pressure relief valve on the hot water heater discharges periodically, this may be due to thermal expansion in a closed water system. Contact the water supplier or your plumbing contractor on how to correct this.

Do not plug the relief valve outlet.

14

Properly maintained, your water heater will provide years of dependable trouble- free service.

It is suggested that a routine preventive maintenance program be established and followed by the user.

It is further recommended that a periodic inspection of the operating controls, heating element and wiring should be made by service personnel qualified in electric appliance repair.

Most electrical appliances, even when new, make some sound when in operation. If the hissing or singing sound level increases excessively, the electric heating element may require cleaning. Contact a qualified installer or plumbing contract to inspect.

At least once a year, lift and release the lever handle on the temperature pressure relief valve, located near the top of the water heater, to make certain the valve operates freely. Allow several gallons to flush through the discharge line to an open drain.

A water heater’s tank can act as a setting basin for solids suspended in the water.It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank. It is suggested that a few quarts of water be drained from the water heater’s tank every month to clean the tank of these deposits.

Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem.

The anode rod should be removed from the water heater’s tank annually for inspection and replaced when more than 6of core wire is exposed at either end of the rod.

Make sure the cold water supply is turned off before removing anode rod.

NOTICE: Do not remove the anode rod from the water heater’s tank, except for inspection and/or replacement,

as operation with the anode rod removed will shorten the life of the glass lined tank and will exclude warranty coverage .

Page 14
Image 14
GE GE30T06MAG, AP12170-4 Care and cleaning of the water heater, Draining the Water Heater, Vacation and Extended Shut-Down

GE30T06MAG, AP12170-4 specifications

The GE AP12170-4, also known as the GE30T06MAG, is a cutting-edge product designed to enhance efficiency and reliability in various industrial applications. This model has garnered attention due to its advanced features, robust technologies, and overall performance characteristics.

One of the standout features of the GE AP12170-4 is its high power capacity, which enables it to handle demanding loads in large industrial environments. The device is engineered to maintain continuous operation even under extreme conditions, making it ideal for critical infrastructures where downtime is not an option. Its durable construction is designed to withstand harsh environmental factors, ensuring longevity and consistent performance.

In terms of technology, the GE AP12170-4 integrates state-of-the-art control systems that facilitate precise monitoring and management of electrical loads. This technology allows users to optimize energy consumption while simultaneously safeguarding against overloads. The built-in diagnostics and data logging capabilities provide real-time insights into operational efficiency and can be crucial for predictive maintenance, reducing unexpected failures and operational costs.

Additionally, this model features advanced safety mechanisms, including surge protection and fault detection systems, which are essential for minimizing risks associated with electrical surges and other anomalies. This focus on safety extends to user-friendly interfaces, which simplify the operation and maintenance of the device. Operators can easily navigate through settings and troubleshoot potential issues, enhancing overall usability.

The GE AP12170-4 also incorporates flexible connectivity options, allowing it to integrate seamlessly into existing systems. Whether using legacy communication protocols or modern networks, users can enjoy versatile connectivity that enhances interoperability with other industrial equipment. This adaptability is vital for facilities undergoing digital transformation and seeking to improve operational efficiency.

Moreover, the design of the GE AP12170-4 emphasizes energy efficiency, contributing to lower operational costs and reduced environmental impact. By optimizing performance and reducing energy waste, it aligns with the growing demand for sustainable practices in industrial operations.

Overall, the GE AP12170-4, or GE30T06MAG, represents a blend of power, reliability, and advanced technology. Its comprehensive features equip industries to meet the challenges of modern operations while prioritizing safety, efficiency, and sustainability. Whether in manufacturing, utility, or larger infrastructure projects, this model stands out as a versatile solution for meeting the demands of today’s industrial landscape.